To learn more about the software which generates this data, please visit Bill, K8CU at:

www.realhamradio.com

NavSymm Proteus

Symmetricom UCCM 1

Symmetricom UCCM 2

Local weather.

Z3801A power-on time
Days Hrs Mins Secs
Since 18 July 2003
             HEWLETT-PACKARD,Z3801A,3542A08179,3543-A +0,"No error"             
Life     +53012                               EFC     +896283
SYNCHRONIZATION ............................................. [ Outputs Valid ]
SmartClock Mode ___________________________   Reference Outputs _______________
>> Locked to GPS                              TFOM     3             FFOM     0
   Recovery                                   1PPS TI -11.7 ns relative to GPS
   Holdover                                   HOLD THR 1.000 us
   Power-up                                   Holdover Uncertainty ____________
                                              Predict  1.1 us/initial 24 hrs
                                                
ACQUISITION ............................................ [ GPS 1PPS CLK Valid ]
Satellite Status __________________________   Time _____ Leap seconds 18 ______
Tracking: 6        Not Tracking: 4            UTC      03:52:45     22 Jan 2018
PRN  El  Az   SS   PRN  El  Az                1PPS CLK Synchronized to UTC
  1  51 271  220     3  15 213                ANT DLY  0 ns
  8  62 164  144    10  30  53                Position ________________________
 11  62 278  151    14  23 117                MODE     Hold
 22  36 208   85    27  25 142                
 28  33 301  128                              LAT      N  53:00:30.905
 32  31  94   72                              LON      W   1:12:00.548
ELEV MASK 10 deg                              HGT               +67.84 m  (MSL)
HEALTH MONITOR ...................................................... [ ERROR ]
Self Test: Err   Int Pwr: OK   Oven Pwr: OK   OCXO: OK   EFC: OK   GPS Rcv: OK