To learn more about the software which generates this data, please visit Bill, K8CU at:

www.realhamradio.com

NavSymm Proteus

Symmetricom UCCM 1

Symmetricom UCCM 2

Local weather.

Z3801A power-on time
Days Hrs Mins Secs
Since 18 July 2003
             HEWLETT-PACKARD,Z3801A,3542A08179,3543-A +0,"No error"             
Life     +52493                               EFC     +896103
SYNCHRONIZATION ............................................. [ Outputs Valid ]
SmartClock Mode ___________________________   Reference Outputs _______________
>> Locked to GPS                              TFOM     3             FFOM     0
   Recovery                                   1PPS TI -16.3 ns relative to GPS
   Holdover                                   HOLD THR 1.000 us
   Power-up                                   Holdover Uncertainty ____________
                                              Predict  2.2 us/initial 24 hrs
                                                
ACQUISITION ............................................ [ GPS 1PPS CLK Valid ]
Satellite Status __________________________   Time _____ Leap seconds 18 ______
Tracking: 6        Not Tracking: 4            UTC      09:48:56     18 Nov 2017
PRN  El  Az   SS   PRN  El  Az                1PPS CLK Synchronized to UTC
  1  86  82  207     8  17 164                ANT DLY  0 ns
  3  54 228  155    19  13 317                Position ________________________
 11  67 150   97    28  22 259                MODE     Hold
 14  39  72  130    32  29  51                
 17  33 308  175                              LAT      N  53:00:30.905
 22  77 203  113                              LON      W   1:12:00.548
ELEV MASK 10 deg                              HGT               +67.84 m  (MSL)
HEALTH MONITOR ...................................................... [ ERROR ]
Self Test: Err   Int Pwr: OK   Oven Pwr: OK   OCXO: OK   EFC: OK   GPS Rcv: OK