To learn more about the software which generates this data, please visit Bill, K8CU at:

www.realhamradio.com

NavSymm Proteus

Symmetricom UCCM 1

Symmetricom UCCM 2

Local weather.

Z3801A power-on time
Days Hrs Mins Secs
Since 18 July 2003
             HEWLETT-PACKARD,Z3801A,3542A08179,3543-A +0,"No error"             
Life     +56625                               EFC     +897753
SYNCHRONIZATION ............................................. [ Outputs Valid ]
SmartClock Mode ___________________________   Reference Outputs _______________
>> Locked to GPS                              TFOM     3             FFOM     0
   Recovery                                   1PPS TI -5.1 ns relative to GPS
   Holdover                                   HOLD THR 1.000 us
   Power-up                                   Holdover Uncertainty ____________
                                              Predict  4.9 us/initial 24 hrs
                                                
ACQUISITION ............................................ [ GPS 1PPS CLK Valid ]
Satellite Status __________________________   Time _____ Leap seconds 18 ______
Tracking: 6        Not Tracking: 5            UTC      19:23:55     18 Apr 2019
PRN  El  Az   SS   PRN  El  Az                1PPS CLK Synchronized to UTC
  8  69 289  184     1  12 247                ANT DLY  0 ns
 10  55  95  156     7  10 273                Position ________________________
 16  26 178   87    11  24 267                MODE     Hold
 18  38 249  118    21  10  71                
 20  38  60   51    30  13 304                LAT      N  53:00:30.905
 27  72 122  188                              LON      W   1:12:00.548
ELEV MASK 10 deg                              HGT               +67.84 m  (MSL)
HEALTH MONITOR ...................................................... [ ERROR ]
Self Test: Err   Int Pwr: OK   Oven Pwr: OK   OCXO: OK   EFC: OK   GPS Rcv: OK